Data Center in DelhiHighly Secure, Lowest Latency, Instant Support

Data Center in Delhi

Data centers of Ricoh located in Delhi are precisely designed with all the facilities requisite for availing 99.95% uptime. Complying with the TIA–942 standards, our data centers are highly capacitive backed–up with world–class UPS modules so that you can work in a stress–free environment. We have not compromised for any measure especially in regards to the security structure. A fire suppression system based on Gas Suppression system, Carbon Mono Oxide System and Water Sprinkler System, 24*7 Electronic Surveillance around the data center, raised flooring and false ceiling to accommodate the wire conduits and fire alarm installations, are all the features with which our data centers are equipped with.

The dual factor authentication including surveillance cameras and biometric entry system makes our data center instrumental so as to minimize the latency and provide remarkable uptime. From state–of–the–art infrastructure to strong security support, our end–to–end data center solutions are a true worth. In addition to a pool of choices, the pay as you use pricing model enables us to provide our clients what they even can't expect in today's overpriced market.

Therefore, making Ricoh your technology partner would be a profitable deal in every aspect.

Specifications of Our Data Center In Delhi/NCR

Some other facilitation details:

Specifications of Our Site
Total Area 1,000 square feet
Floor to Floor Height 15'
Raised Floor to Ceiling Height 12 ft
Raised Floor Height 750 mm
Raised Floor Loading Capacity 1350 Kg/sq.m
Security
Entry to Sever Hall Punch Cards
Entry to all Critical Areas Proximity Readers
CCTV Cameras External and Internal
CCTV Recording DVR
Video Storage Recording Duration 30 days
24*7 Guards Yes
Power
Power Feed From BSES
Transformer Capacity 3*2000kVA
Diesel Generator 3*2000kVA
UPS N:N, 12*5000KVA
Battery Back Up 15 Minutes at Full Load
Standard Power Per Rack 32A/16A
STS 3 and 6 kVA at Racklevel
FIRE PROTECTION
HSSD Yes
Fire Alarm System Addressable
Type of Suppression System Novec
Suppression Mode Automatic/Manual
POWER
Power Feed From BSES
Transformer Capacity 3*2000kVA
Diesel Generator 3*2000kVA
UPS N:N, 12*5000KVA
Battery Back Up 15 Minutes at Full Load
Standard Power Per Rack 32A/16A
STS 3 and 6 kVA at Racklevel
Air Conditioning/Environment
Type Redundancy Precision AC with N+1 Redundancy
Temperature Nominal Set Point 20 Degree Celcius
Humidity Nominal Set Point 50%
Raised Floor Height 750 mm
Raised Floor Loading Capacity 1350 Kg/sq.m